Search results for "Shielded cable"
showing 9 items of 9 documents
Magnetized boxes for housing polarized spins in homogeneous fields
2010
Abstract We present novel types of permanently magnetized as well as current powered boxes built from soft-ferromagnetic materials. They provide shielded magnetic fields which are homogeneous within a large fraction of the enclosed volume, thus minimizing size, weight, and costs. For the permanently magnetized solutions, homogenization is achieved either by an optimized distribution of the permanent field sources or by jacketing the field with a soft-ferromagnetic cylindrical shell which is magnetized in parallel to the enclosed field. The latter principle may be applied up to fields of about 0.1 T. With fields of about 1 mT, such boxes are being used for shipping spin-polarized 3 He worldw…
Partial Discharge on-line measures in cable's EPR insulation
2004
In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.
Quantitative Determination of Renal 99mTc-MAG3 Clearance. A Comparison of Results Acquired Simultaneously in Whole Body Geometry and with a Gamma Cam…
1997
289 patients were simultaneously investigated with a partially shielded whole body counter (Oberhausen) and in camera technique to correlate the values of the MAG3-clearance. Good correlation was found for the often used times schedules of taking blood samples. Late blood samples increase high clearance values in both methods slighly. The shape of the ROI has no influence using camera technique. We conclude, that camera technique can replace the Oberhausen method with a partially shielded whole body counter.
A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate Ir-192 brachytherapy
2017
PurposeA joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) Ir-19…
SU-FF-T-365: Practical Reconstruction Method for 3D CT-Based Brachytherapy with Shielded Colpostats
2006
Introduction and purpose.‐ The most extended worldwide HDR and PDR afterloading machines are from Nucletron, using the Plato Treatment Planning System (TPS) to perform the clinical dosimetry. The Fletcher‐Williamson (FW) vaginal colpostat applicators are widely used with these machines, they are made of a very dense material (densimet‐17) which allows shielding up to 50% of the dose. Almost all the TPS have incorporated the CT‐Based Brachytherapy (BT), in which the CT catheters and applicators reconstruction is based on contiguous CT transverse slices where the user points the catheter position. The problem with these applicators is the production of artefacts that makes the reconstruction …
Modeling propagation for high-power cylindrical microwave applicators
2001
In this letter, the dispersion characteristics and energy configurations of a cylindrical partially filled waveguide or lossy multilayered rod shielded by a metallic enclosure are presented for several modes. These parameters are obtained by a numerical simulation based on the residues theory. © 2001 John Wiley & Sons, Inc. Microwave Opt Technol Lett 30: 192–195, 2001.
Overcoming synchronization issues in wireless technology Partial Discharge measurement
2016
In this paper, several aspects of the fundamentals of wireless Partial Discharge (PD) measurements are first discussed. Then, the relevance of the problem of voltage synchronization in PD wireless diagnosis is outlined. When portable instruments are used for PD detection, the main issue is the voltage measurement at the site where the PD detection is carried out. When such analysis is carried out over shielded cables, the AC (50/60 Hz) voltage reference signal is not easily detectable, while one of the basic parameters for PD diagnosis, the displacement of the inception voltage of the PD as compared to the reference voltage, is not available. Even if highperformance sensors are readily avai…
A mobile robot for vigilance tasks improved with a new robust and low cost communications system immune to attacks with EMI noise
2006
This work pretends to develop a robot for vigilance tasks that are able to tolerate diverse kinds of attacks and be able to operate in environments with elevated electromagnetic noise, being even immune to sabotage provoked by means of high electromagnetic fields. A new CAN based communications system that interconnects the different devices that compose the mobile robot has been developed to achieve this goal. The system is based on a shielded communications hub, that interconnects diverse nodes by means of CAN. On the other hand, the point to point communication between each node and the hub is carried out by means of economic optical fiber. With this approach all robot devices are connec…
A rotating wheel system for the detection of spontaneously fissioning nuclides from heavy ion reactions
1981
Abstract A rotating wheel system for the detection of spontaneously fissioning reaction products from heavy ion reactions was developed. In this system products recoiling from a rotating target wheel are stopped in a catcher foil stack which can be rotated at various velocities up to 80 rotations per second. All products emitted within a wide emission cone are stopped in the catcher foils and are rotated into shielded positions with stationary fission-track detectors positioned on both sides of each rotating foil. This technique allows a sensitive detection of spontaneously fissioning nuclides over a broad range of half-lives from 1 ms to about 1 d. By post-bombardment exposure of the catch…